Virtual Poster Session

Welcome to the Virtual Poster Session, a new and powerful tool for networking and information exchange. Here you can share your work, search though the poster library, and start a dialogue with others in your field. Each uploaded poster that pertains to force measurement and testing can currently be used to apply for an academic travel scholarship; please see the Scholarships page for application details and deadlines.

Elasto-Plastic Computational Modelling of Damage Mechanisms in Total Elbow Replacements

Conference: 29th International Society for Technology in Arthroplasty (ISTA) Congress
Abstract: As a treatment for end-stage elbow joint arthritis, total elbow replacement (TER) results in joint motions similar to the intact joint; however, bearing wear, excessive deformations and/or early fracture may necessitate early revision of failed implant components. A finite element model of a TER assembly was developed based on measurements from a Coonrad-Morrey implant (Zimmer, Inc., Warsaw, IN) using nonlinear elasto-plastic UHMWPE material properties and a frictional penalty contact formulation. The loading scenario applied to the model includes a flexion-extension motion, a joint force reaction with variable magnitude and direction and a time varying varus-valgus (VV) moment with a maximum magnitude of 13 N.m, simulating a chair-rise scenario as an extreme loading condition. Model results were compared directly with corresponding experimental data. Experimental wear tests were performed on the abovementioned implants using a VIVO (AMTI, Watertown, MA) six degree-of-freedom (6-DOF) joint motion simulator apparatus. The worn TER bushings were scanned after the test using micro computed tomography (μCT) imaging techniques, and reconstructed as 3D models. Contact pressure distributions on the humeral and ulnar bushings correlate with the sites of damage as represented by the μCT data and gross observation of clinical retrievals. The results demonstrate UHMWPE bushing damage due to different loading protocols. Numerical results demonstrate strong agreement with experimental data based on the location of deformation and creep on bushings and exhibit promising capabilities for predicting the damage and failure mechanisms of TER implants.
Listed In: Biomechanical Engineering, Biomechanics, Biotribology, Mechanical Engineering, Orthopedic Research,
Tagged In: Implant Failure, Total Elbow Replacement, UHMWPE Wear, Wear Simulation

View PDF | Contact Author